Safety Guidelines For Maintenance of Fire Dampers2484982

Материал из OrenWiki
Перейти к: навигация, поиск

Fire Dampers are usually passive fire protection systems which are engineered in the manner that it gets close if you have an increase in temperature in order to stop the spread of fire.

Fire Dampers are used for avoiding fire, so proper steps ought to be taken for proper repair off these dampers. It is important to avoid the spread of fireplace that is caused inside the ductwork and also prevent transmission of flame where ductwork penetrate fire barriers.

Initially, proper testing should be carried out during the time of its installation that is operational testing ought to be done of fire damper in order to ensure that it's in working order then there is full access to it too becasue it is components, verification should be carried out that all the devices are placed properly in their appropriate places, as well as other important verifications. All of this testing done should then be documented which includes all detailed information in regards to the fire damper instructions regarding its installation.

After the period of 12 months of installation of fire and smoke dampers, it is crucial being inspected according to the National Fire Protection Standard and then the frequency needs to be every Four years and 6 years for hospitals.


These activities must be performed at the time of inspection:-

1] The fusible link 165 degree where it really is applicable needs to be removed for testing purpose.

2] All dampers should be operated to be able to verify they close properly and fully to stop spread of fireplace.

3] When the latch is being provided of computer ought to be checked and moving parts lubricated if needed.

4] There isn't any interference as a result of rust, misalignment, damaged frames or blades, defective hinges or parts, or bent tracks ought to be confirmed.

5] All inspections done of fireside and smoke dampers needs to be documented properly which include the facts like the location of inspection, date of inspection, inspector, and applicable deficiencies.

6] If the damper is not operating properly compared to the repairs shall begin without having done any any delay.

Smoke dampers are intended for installation in ducts and air transfer openings which can be specially designed to stand up to the passage of air and smoke. Other security precautions which should be cared for are:-

• It must be checked on a proper basis the external components of each damper for indications of physical damage, obstructions preventing proper functioning, defective and missing parts, and proper labeling.

• Verification should be carried out concerning the proper sealing from the damper.

• Make certain that damper is ready close fully.

• Tthere shouldn't be blockage from your closure and ought to not be penetrated by any foreign objects because it affects fire damper operations.

• It should be ensured that if fusible link is damaged compared to being substituted for a hyperlink of the size, temperature, and load rating.

Thus testing and safety precautions are necessary to become done so concerning make sure that it functions at its best during the time of fire and life safety event where it is most significant to operate. It's important for doing inspections regularly so that the method is always ready because we can't predict if the unexpected event is going to occur.