Fire Dampers are usually passive fire protection systems that are engineered in the manner it gets close when there is a boost in temperature so as to stop the spread of fire.

Fire Dampers are used for avoiding fire, so proper steps ought to be taken for correct upkeep of these dampers. It is useful to avoid multiplication of fireside which is caused inside the ductwork and also prevent transmission of flame where air ducts penetrate fire barriers.

Initially, proper testing should be done during its installation which is operational testing ought to be done of fireside damper to guarantee that it is functional then there is full access to it too becasue it is components, verification should be done that all the tools are placed properly in their appropriate places, along with other important verifications. All this testing done should then be documented which includes all details in regards to the fire damper instructions regarding its installation.

After the duration of one year of installation of fire and smoke dampers, it's important to be inspected according to the National Fire Protection Standard and then the frequency should be every Four years and 6 years for hospitals.


The following activities must be performed during the time of inspection:-

1] The fusible links for fire dampers where it's applicable needs to be removed for testing purpose.

2] All dampers needs to be operated so as to verify that they close properly and fully to avoid spread of fire.

3] When the latch has been provided laptop or computer needs to be checked and moving parts lubricated if required.

4] There is no interference as a result of rust, misalignment, damaged frames or blades, defective hinges or parts, or bent tracks needs to be confirmed.

5] All inspections done of fire and smoke dampers ought to be documented properly including the details just like the location of inspection, date of inspection, inspector, and applicable deficiencies.

6] In the event the damper isn't operating properly compared to repairs shall begin without having done any any delay.

Smoke dampers are meant for installation in ducts and air transfer openings which are specially engineered to resist the passage of air and smoke. Other security precautions which should be taken care of are:-

• It ought to be checked on the proper basis that the external pieces of each damper for signs of physical damage, obstructions preventing proper functioning, defective and missing parts, and proper labeling.

• Verification should be carried out about the proper sealing from the damper.

• Make certain that damper is able close fully.

• There shouldn't be blockage from your closure and should not penetrated by foreign objects as it affects fire damper operations.

• It ought to be ensured that if fusible link is broken than being substituted for a link of the size, temperature, and load rating.

Thus testing and security precautions are important to be done this concerning make sure that it works at its best during fire and life safety event where it is most significant to work. It is crucial for doing inspections regularly so that the method is always ready because we don't know once the unexpected event will probably occur.