Fire Dampers are usually passive fire protection systems that are specially engineered in how it gets close if you find an increase in temperature to be able to stop the spread of fireside.

Fire Dampers bring avoiding fire, so proper steps should be taken for proper repair off these dampers. It is important to avoid multiplication of fireside which can be caused within the ductwork and also prevent transmission of flame where ductwork penetrate fire barriers.

Initially, proper testing should be done at the time of its installation which is operational testing ought to be done of fireplace damper in order to ensure that it is in working order then there is full usage of it as well as its components, verification ought to be done that all the tools are placed properly within their spots, along with other important verifications. All of this testing done should then be documented which includes all more information about the fire damper instructions regarding its installation.

Following the period of twelve months of installing fire and smoke dampers, it is necessary to become inspected according to the National Fire Protection Standard and so the frequency needs to be every Four years and 6 years for hospitals.


These activities should be performed during the time of inspection:-

1] The fusible link 165 degree where it's applicable ought to be removed for testing purpose.

2] All dampers needs to be operated to be able to verify which they close properly and fully to avoid spread of fire.

3] In the event the latch is being provided than it needs to be checked and moving parts lubricated if necessary.

4] There's no interference because of rust, misalignment, damaged frames or blades, defective hinges or parts, or bent tracks should be confirmed.

5] All inspections done of fire and smoke dampers should be documented properly which include the facts like the location of inspection, date of inspection, inspector, and applicable deficiencies.

6] When the damper isn't operating properly than the repairs shall begin without having done any any delay.

Smoke dampers are meant for installation in ducts and air transfer openings which are engineered to resist the passage of air and smoke. Other safety precautions which needs to be cared for are:-

• It should be checked on the proper basis how the external components of each damper for signs and symptoms of physical damage, obstructions preventing proper functioning, defective and missing parts, and proper labeling.

• Verification should be done about the proper sealing from the damper.

• Make certain that damper is ready close fully.

• There should be no blockage from the closure and ought to not be penetrated by any foreign objects as it affects fire damper operations.

• It should be ensured that when fusible link is damaged than being substituted for a link of the size, temperature, and load rating.

Thus testing and security precautions are important being succeeded in doing so as to ensure that it functions at its best at the time of fire and life safety event where it really is most significant to operate. It is crucial for doing inspections regularly so that the system is always ready because we never know when the unexpected event will occur.